A standard SMA termination, RT45SM presents a matched 50 ohm load at a male interface from DC to 4 GHz.
Nothing exotic about the thermal path at this rating: a small resistive element in a metal body handles the power with margin.
The DC to 4 GHz specification is the band over which the element is guaranteed matched; treat anything above it as out of tolerance.
Key numbers: 5 W dissipation; VSWR 1.15:1 max; 50 ohm impedance; DC to 4 GHz; passivated stainless steel body.
In service it usually sits where a signal would otherwise hit an open circuit: on standby outputs, at the ends of unterminated lines, and across power splitters during testing.
FAQ – Can it measure power? No, it absorbs power without indicating it. To measure, use a power sensor, or sample the line with a coupler into a sensor.
FAQ – Does mounting orientation matter? For the finned bodies, yes: they are rated to convect with the fins vertical. Enclosing one or mounting it against a panel cuts the rating.
The cylindrical body is the classic bench shape: it screws straight onto the port and needs no mounting hardware.
FAQ – What VSWR should I expect? The figure in the specs below is the guaranteed maximum across the band; a healthy termination typically measures better on the bench.





![[Premium Pick] BNC Male Coaxial Termination | Economy, DC-8GHz, 2 W, Round, Nickel-Plated Brass Connector](https://rfspect.com/wp-content/uploads/2026/09/RT82BM-NBA.png)

Reviews
There are no reviews yet.