A standard 4.3-10 termination, RT42PM presents a matched 50 ohm load at a male interface from DC to 4 GHz.
Low dissipation means the body can stay minimal: a short in-line termination that can live on a spare port indefinitely.
The DC to 4 GHz specification is the band over which the element is guaranteed matched; treat anything above it as out of tolerance.
Key numbers: 2 W dissipation; VSWR 1.2:1 max; 50 ohm impedance; DC to 4 GHz; ternary alloy plated brass body.
Typical use is leaving an unused port terminated, dummy-loading a transmitter during alignment, or providing a stable 50 ohm sink at the far end of a line under test.
FAQ – Does mounting orientation matter? For the finned bodies, yes: they are rated to convect with the fins vertical. Enclosing one or mounting it against a panel cuts the rating.
FAQ – What VSWR should I expect? The figure in the specs below is the guaranteed maximum across the band; a healthy termination typically measures better on the bench.
The cylindrical body is the classic bench shape: it screws straight onto the port and needs no mounting hardware.
FAQ – Is ‘dummy load’ something different again? It is a third name for the same component: a connectorised resistor that soaks up RF power instead of reflecting it.






![[Premium Pick] SMA Male Coaxial Termination | Economy, DC-18GHz, 1 W, Round, Passivated Stainless Steel Connector](https://rfspect.com/wp-content/uploads/2026/09/RT181SME.png)
Reviews