Where a L29(DIN 7/16) port has to be left matched, RT650DM does the job: a male 50 ohm termination rated 50 W, DC to 6 GHz.
The rating sits between bench pads and rack loads: the body carries enough metal to run at rated power for hours, with no fan and no derating curve below the limit.
Key numbers: 50 W dissipation; VSWR 1.25:1 max; 50 ohm impedance; DC to 6 GHz; ternary alloy plated brass body.
Typical use is leaving an unused port terminated, dummy-loading a transmitter during alignment, or providing a stable 50 ohm sink at the far end of a line under test.
FAQ – What VSWR should I expect? The figure in the specs below is the guaranteed maximum across the band; a healthy termination typically measures better on the bench.
FAQ – Is ‘dummy load’ something different again? It is a third name for the same component: a connectorised resistor that soaks up RF power instead of reflecting it.
Round in-line construction keeps the part at home on a patch panel or the end of a test lead.
The DC to 6 GHz specification is the band over which the element is guaranteed matched; treat anything above it as out of tolerance.
FAQ – Does mounting orientation matter? For the finned bodies, yes: they are rated to convect with the fins vertical. Enclosing one or mounting it against a panel cuts the rating.




![[Premium Pick] SMA Male Coaxial Termination | Economy, DC-18GHz, 1 W, Round, Passivated Stainless Steel Connector](https://rfspect.com/wp-content/uploads/2026/09/RT181SME.png)


Reviews