A factory-terminated assembly, RCT360-KMKF-L runs 2.92mm(K,SK) Male to 2.92mm(K,SK) Female Millimeter-Wave High-Performance Test on RCT360 cable, specified from DC to 40 GHz and ordered by length.
One end is male and the other female, so match each end against the port or cable it has to meet.
Match is specified at VSWR 1.2:1 maximum; on a healthy assembly most of the reflection sits at the two connector interfaces, which is why mating-plane care matters even on a cable.
Key numbers: DC to 40 GHz; 3.44 dB/m max at 40 GHz; VSWR 1.2:1 max; 50 ohm impedance.
Lengths are made to order: state the finished length and quantity, and each assembly is terminated, tested and labelled before it ships.
Typical use is the fixed cabling of a test bench: instrument to fixture, filter to analyser, or anywhere a flexible run has to hold its performance for the life of the set-up.
FAQ – Are both connector genders available? Yes, the title states the pairing. If the combination you need is not listed, most pairings within the same frequency class can be built to order.
FAQ – How is it tested before shipping? Each assembly is continuity-checked and insertion-loss tested, and the results are tied to the part number and length marked on the jacket.
The cable is phase-stable: electrical length changes very little with flexing or temperature, so the assembly can live inside a measurement path without calibrating around it. The cable is the high-performance type of the series: tighter tolerances on the electricals and better consistency from unit to unit.
The datasheet quotes 3.44 dB maximum insertion loss per metre at 40 GHz; the actual assembly is tested to that figure before it ships.
FAQ – Does the length change the phase? Yes, phase scales with electrical length. If phase matters, order the assembly to a stated electrical length tolerance rather than a mechanical one.







Reviews
There are no reviews yet.