RA18N01F-TBA carries an N female interface on one end and a second N female interface on the other, in a single four-hole flange housing specified to 18 GHz.
Both ends are female, so it joins two ports or cables of the same sex; the part number states the pairing.
Key numbers: VSWR 1.25:1 max; 50 ohm impedance; tri-metal plated brass body.
FAQ – What torque should I use? Use the torque recommended for the interface standard of each end. Over-tightening is the usual cause of a damaged mating plane.
FAQ – Can I run it above 18 GHz? The part is specified to 18 GHz. Above that the VSWR and loss figures are no longer guaranteed, so treat it as out of band.
The four-hole flange bolts the adapter rigidly to a chassis wall or fixture plate, so the interface cannot rotate while a cable is torqued onto it. It also earns its keep as a sacrificial adapter on an instrument port: letting wear land on the adapter instead of the calibrated connector.
DC to 18 GHz covers the great majority of lab work, from baseband through Ku-band. The tri-metal plating stack on the brass body balances conductivity, wear resistance and corrosion protection.
FAQ – What is the worst-case loss? The datasheet below lists maximum insertion loss; the datasheet figure applies across the band.