Where a N port has to be left matched, RT4200NFA does the job: a female 50 ohm termination rated 200 W, DC to 4 GHz.
At the rated power the element runs hot by design; the body is dimensioned so that heat reaches the air fast enough for continuous duty.
From DC to 4 GHz the termination holds its VSWR figure; above the limit the match degrades, which matters if you rely on the load to absorb reflected power.
Key numbers: 200 W dissipation; VSWR 1.2:1 max; 50 ohm impedance; DC to 4 GHz; ternary alloy plated brass body.
In service it usually sits where a signal would otherwise hit an open circuit: on standby outputs, at the ends of unterminated lines, and across power splitters during testing.
FAQ – Can it measure power? No, it absorbs power without indicating it. To measure, use a power sensor, or sample the line with a coupler into a sensor.
FAQ – What VSWR should I expect? The figure in the specs below is the guaranteed maximum across the band; a healthy termination typically measures better on the bench.
The rectangular body is a finned heatsink: mount it with the fins vertical and it holds its rating indefinitely.
FAQ – Does mounting orientation matter? For the finned bodies, yes: they are rated to convect with the fins vertical. Enclosing one or mounting it against a panel cuts the rating.